{"wiki":"en","slug":"integration-2-0-in-sprechanlage","markdown":"# Integrating the Behnke Sprechstelle 2.0 into the Behnke Intercom System\n\n\n<!-- block: einleitung -->\n## 1.   Introduction \n\nThis setup guide describes how to integrate a Behnke SIP 2.0 into an existing Behnke intercom setup.\nIt is assumed that:\n\n- all devices have already been started,\n- the basic initial setup has been completed,\n- valid IP addresses have been assigned,\n- the web interfaces of all devices are reachable,\n- a Behnke indoor station with a Behnke Station in intercom mode has already been set up.\n\nIf this has not yet been done, the settings can be made using the setup guide\n\n[A Behnke door station calls two indoor stations at the same time](Eine Behnke-Sprechstelle ruft zwei Innenstationen gleichzeitig an)\n\n.\n\nRecommendation: For this setup, it is strongly recommended to configure fixed IP addresses (static IP addresses) on all devices. This ensures that direct IP dialing and the camera connection keep working permanently and that the devices do not lose each other after a restart or a DHCP change.\n\n<!-- block: netzwerkuebersicht -->\n## 2.   Network overview\n\n| Device             | IP address   |\n| ------             | ------       |\n|Behnke Station      |192.168.50.85 |\n|Behnke indoor station |192.168.50.173|\n|Behnke SIP 2.0      |192.168.50.217|\n|Camera of the SIP 2.0  |192.168.50.182|\n\n![Innestelle_mit_Behnke_Sprechstelle_2.0_E_Mit_ipadesse_A](uploads/520084c9421f49f250ddd41a2c5c4824/Innestelle_mit_Behnke_Sprechstelle_2.0_E_Mit_ipadesse_A.png){width=564 height=464}\n\n<!-- block: konfiguration-der-behnke-sip-2-0 -->\n##    3. Configuring the Behnke SIP 2.0\n\nThe Behnke SIP 2.0 does not support an intercom mode. The door station must therefore register itself as a SIP participant. In addition, direct IP dialing must be enabled.\n\n<!-- block: selbstanmeldung-der-sip-2-0 -->\n##   3.1 Self-registration of the SIP 2.0\n\nMenu:\n\nNetwork → SIP settings\n\nMake the following settings:\n\n| Setting                     | Value |\n| ------                      | ------ |\n| Account                     |   100     |\n| Phone number / user name    |    100    |\n|  Name                       |   100     |\n|SIP authentication ID        |    100    |\n|SIP authentication PIN       | 100       |\n|SIP authentication domain    |  192.168.50.217      |\n|SIP registrar                |  192.168.50.217      |\n\nNote: In this scenario, the SIP 2.0 registers at its own IP address. This allows the indoor station to reach the door station via direct IP dialing without requiring an external SIP server.\n\n![2.0_selbstanmeldung_](uploads/f166e7a1492dbc2d42145237f50f7ce1/2.0_selbstanmeldung_.jpg){width=900 height=492}\n\n<!-- block: direkte-ip-anwahl-aktivieren -->\n##   3.2 Enabling direct IP dialing\n\nMenu:\n\nNetwork → SIP settings\n\nEnable the following setting:\n\n- Direct IP dialing: Active\n\n![2.0_Direkte_IP-anwahl](uploads/423bb632ddad7f3ba0b7ddc3a56c008e/2.0_Direkte_IP-anwahl.jpg){width=900 height=479}\n\n<!-- block: sip-anmeldung-pruefen -->\n##   3.3 Checking the SIP registration\n\nAfter saving the settings, the status screen of the SIP 2.0 should show the status \"Registered\".\n\n![2.0_Sipanmeldung](uploads/aa42135015abe38ff9daa1ae64933cca/2.0_Sipanmeldung.jpg){width=900 height=443}\n\n<!-- block: zielrufnummer-in-der-taste-hinterlegen -->\n##  3.4 Storing the target number in the button\n\nSo that the SIP 2.0 can dial the indoor station directly via IP, the IP address of the indoor station must be stored in the button configuration.\n\nMenu:\n\nSelect number\n\nEnter the following number:\n\n| Button | Number |\n| ------ | ------ |\n| Number|192.168.50.173|\n\nNote: Direct IP dialing only works if the IP address of the remote station remains unchanged. The use of static IP addresses is therefore strongly recommended.\n\n![2.0_Taste_Ipadresse_nummer](uploads/bc64afcccc9d01930a7397e5b960a6c7/2.0_Taste_Ipadresse_nummer.jpg){width=900 height=459}\n\n\n\n\n<!-- block: konfiguration-der-behnke-innenstation -->\n## 4. Configuring the Behnke indoor station\n\n4.1 Setting the number of IP stations\n\nMenu:\n\nIntercom\n\nUnder IP stations, set the number to 1.\n\n![in_innestation__Sprechanlagenmenü](uploads/9490e20cc57899456f14f038b2e859ac/in_innestation__Sprechanlagenmenü.jpg){width=819 height=600}\n\n\n\n<!-- block: sip-2-0-hinzufuegen -->\n##   4.2 Adding the SIP 2.0\n\nThen add the SIP 2.0 as a new station.\n\n![Innenstation_2.0_dazufügen](uploads/25efeedbcc6c33fc31005130e1f16824/Innenstation_2.0_dazufügen.jpg){width=805 height=600}\n\nMake the following settings:\n\n| Setting                           | Value |\n| ------                            | ------ |\n|Type                               |BT-IP 2 Generation   |\n|Name                               |Serie 2.0        |\n|Number                             |sip:192.168.50.217        |\n|IP address or host name            |192.168.50.217      |\n|Access type                        |Access       |\n|UDP code to open the access        |-        |\n|DTMF code to open the access       |0        |\n|Visualized opening duration        |5        |\n|Camera type                        |Behnke Type A        |\n|IP address or host name of the camera|192.168.50.182        |\n|Camera user                        |  root      |\n|Camera password                    |  Admin                 |\n|Preferred view                     |    Center    |\n\n![Innstelle_IP_anlegen_3](uploads/ac8d32f4ec2970d79fe9df50d40dab41/Innstelle_IP_anlegen_3.jpg){width=822 height=600}\n\n<!-- block: funktionspruefung -->\n##   5. Function test\n\nAfter completing the configuration, the following check should be performed:\n1. Trigger a call at the SIP 2.0.\n2. The indoor station should ring.\n3. The camera image of the SIP 2.0 should be displayed on the indoor station.\n4. The door opener function should be tested.\n\n \n\n\n> [!IMPORTANT]\n>The SIP 2.0 and the indoor station can be registered with an external SIP server at the same time. The self-registration of the SIP 2.0 described here does not affect the registration with another SIP server.\n\n---\n\n> [!NOTE]\n> Recommendation: For installations with direct IP dialing and a camera connection, fixed IP addresses should always be used.\n> Note: Direct IP dialing only works if both devices are in the same network or if there is a suitable routing connection between the networks.\n","lastModified":"2026-10-14T13:47:15+02:00"}