Wiki Behnke-Station

Configuring Two Door Stations That Call Two Indoor Stations – with Cross-Group Button Function

Machine-translated

1. Introduction

This setup guide describes the configuration of Behnke intercom stations and Behnke indoor stations in IP intercom mode. The setup shown is based on a network structure with a PoE switch, through which both the power supply and the network communication of the devices are provided.

Depending on the scenario, different group and ID assignments can be configured to implement the desired call logic between the intercom station and the indoor stations. It is assumed that:

  • all devices are connected to a PoE switch and have already started up,
  • the basic initial commissioning of the devices has been completed,
  • valid IP addresses have been assigned,
  • the web interfaces of the devices are reachable.

This guide describes only the respective group, ID and button configuration.

2. Setup overview

Functional description

Device A

Button 1 → calls indoor station A (group 1)

Device B

Button 1 → calls indoor station B (group 2)

Button 2 → calls indoor station A (group 1, cross-group)

Schamatischer_Aufbau__B_zwei__farben

3 Configuration of door station A

3.1 Assign intercom operating mode and name

Operating mode: IP intercom

Device name: enter the device name in the "Name" field (e.g. "Entrance A").

This name is shown on the indoor station when a call comes in.

Betreibsart_und_Name__markiert_Sprechstelle

3.2 Set the group

Group: 1

Sprechstelle_Gruppe_1_

3.3 Button assignment

Button 1 → com:1

Explanation:

com:1 calls ID 1 within the configured group (group 1). This means door station A calls indoor station A.

Tasten_mit_com_1_

4 Configuration of indoor station A

4.1 Assign intercom operating mode and name

Operating mode: IP intercom

Device name: e.g. "Monitor Group 1"

Innenstelle__Modus_und_Gerätename__A

4.2 Assign group and ID

Group: 1

ID: 1

The call is only delivered correctly if group and ID match.

IP-Sprechanlage_Innensprechstelle__Gruppe_1_ID_1

5 Configuration of door station B

5.1 Assign intercom operating mode and name

Operating mode: IP intercom

Device name: enter the device name in the "Name" field (e.g. "Entrance B").

This name is shown on the called indoor station

Betreibsart_und_Name__markiert_Sprechstelle

5.2 Set the group and define the device name

Group: 2

Sprechstelle_Gruppe_2

5.3 Button assignment

Button 1 → com:1 → calls indoor station B (group 2, ID 1)

Button 2 → com:101 → calls indoor station A (group 1, ID 1)

Tasten__Gruppe_A_und_Gruppe_B_NEU_1247x915

Explanation of cross-group dialing

The destination address is composed as follows: com:group-ID

The following applies: First digit = target group Next two digits = ID Example:

  • com:101
  • "1" = group 1
  • "01" = ID 1

This makes it possible to dial a specific indoor station in group 1 from group 2.

6 Configuration of indoor station B

6.1 Assign intercom operating mode and name

Operating mode: IP intercom

Device name, e.g. "Monitor Group 2"

Innenstelle_Betreibart_und_Name_B

6.2 Assign group and ID

Group: 2

ID: 1

Innenstelle_Gruppe_2_ID_1

7. Function test

After completing the configuration, perform the following test:

  • Press button 1 on door station A → Only indoor station A rings
  • Press button 1 on door station B → Only indoor station B rings
  • Press button 2 on door station B → Indoor station A rings

If the call is not delivered correctly, check the following points:

Group assignment ID setting Correct entry of the destination address (e.g. com:1 or com:101) Network connection

Technical note

Cross-group dialing via com:101 enables flexible call concepts, for example:

  • The rear entrance additionally calls the main monitor
  • The gate calls the house and the office
  • Gatekeeper function
  • This structure is particularly useful for larger systems.
✕