Setup Guide for the DNAKE Indoor Station A 416 W
This setup guide describes how to put a DNAKE indoor station A 416 W into operation together with a Behnke Station. The following assumes that the basic configuration of the DNAKE indoor station A 416 has already been completed, and we limit ourselves exclusively to the steps required to commission the Behnke Station.
It is assumed that the Behnke-Station is already set up to the extent that access to the web interface is possible. If this is not the case, please follow the instructions provided with your base electronics (manuals) and refer to the technical manualRecently updated — within the last 72 hours to complete the basic setup.
Related setup guide(s) and notes
The DNAKE indoor station A416 W and the Behnke Station must be in the same network to enable direct communication.

Help with configuring a static IP address on the DNAKE indoor station A416 W can be found in this setup guide.
1. Setting up the Behnke Station
- Open your browser
- Open the web interface of the Behnke Station
- Log in

- In the sidebar on the left, click the menu item
- Navigate to the section Cancel connection
- Set the option Automatically after opening the access to the value yes

- In the sidebar on the left, click the menu item
- Navigate to the section IP audio
- Set the option Expert settings to the value configure individually

- Further configuration options are displayed
- Set the option Receive gain to the value 6 dB

- In the sidebar on the left, click the menu item
- Navigate to the section SIP direct calls
- Set the option Allow SIP direct calls to the value yes

-
Navigate to the section SIP account 1 or SIP account 2
-
Set the option Register to the value yes
-
Use the assignments from the following table and enter the information in the corresponding input fields (in the section SIP account 1, or SIP account 2 if applicable) of your Behnke Station.
Behnke Station field Value Phone number/user name 100 User ID 100 Password 100 Server IP address of the Behnke Station

- In the sidebar, click
- Wait a moment until the Behnke Station is reachable again
- If the registration is successful, the option Registration status changes to the value registered. If this is not the case, please check the previous steps again.

- Navigate to the section Early Media
- Set the option For outgoing calls to the value reject

- In the sidebar on the left, click the menu item
- Navigate to the section of the button to be configured, e.g. Button 1
- Set the option Action to the value Call
- Set the option Phone number to the IP address of your DNAKE device

Installation notes
- Configure a static IP address for both devices or create a reservation based on the MAC address in your DNS server. This is important because the Behnke Station can only reach your DNAKE A416 W via direct IP dialing. Feel free to use our corresponding setup guide.
- With group calls, an image preview is not possible.
- Group calls with simultaneous connection of participants via a SIP server and via direct IP call are not possible.
- If calls cannot be answered on the DNAKE indoor station, please reinstall the software. Danke_A_461_Wiki.zipPlanned
2. FAQ
Note
There is currently no content available here yet. As soon as content is planned, the pages will be marked as planned. Feel free to use the Report a problem function on the right in the toolbar to request new content, ask questions, or report anything that is unclear.
You can also give feedback after every heading, so that we can continuously improve our wiki:
- Move your mouse over the heading
- A small ? appears
- Click the small ?
We welcome every suggestion, every correction and every idea for improvement.